UP floor controller 50x50, AC 230V, 1NO contact, 16A, lamps: heat, reduced operation. Load interruption according to EN 50559 image 1
UP floor controller 50x50, AC 230V, 1NO contact, 16A, lamps: heat, reduced operation. Load interruption according to EN 50559 image 2
UP floor controller 50x50, AC 230V, 1NO contact, 16A, lamps: heat, reduced operation. Load interruption according to EN 50559 image 3
UP floor controller 50x50, AC 230V, 1NO contact, 16A, lamps: heat, reduced operation. Load interruption according to EN 50559 thumbnail 1
UP floor controller 50x50, AC 230V, 1NO contact, 16A, lamps: heat, reduced operation. Load interruption according to EN 50559 thumbnail 2
UP floor controller 50x50, AC 230V, 1NO contact, 16A, lamps: heat, reduced operation. Load interruption according to EN 50559 thumbnail 3

UP floor controller 50x50, AC 230V, 1NO contact, 16A, lamps: heat, reduced operation. Load interruption according to EN 50559

In stock: No Vendor stock: No Minimal order quantity: 1
Price (excl. VAT):
100,27 €
This price is valid until 31.12.24
EAN: 4017254143588
MPN: 517816155100
Box: 1

Technical Information

Item condition New
Manufacture name UP floor controller 50x50, AC 230V, 1NO contact, 16A, lamps: heat, reduced operation. Load interruption according to EN 50559
Brand EBERLE
Categories Control devices
Country of origin DE
Harmonized System Code 9032 1020 00
Colour White
Width 84 mm
Height 84 mm
Depth 16.3 mm
RAL-number 9010
Connection 3-/4-wire
With display No
With thermal feedback Yes
Type of power supply 230 V
Contact type Normally open contact (NO)
Measuring range 5-50 °C
Operation Turn
Explosion-proof No
Degree of protection (IP) IP30
Sensor/feeler type Resistance sensor
Standby power consumption (solstandby) 0.5 W
IFTTT support available No
Regulation type on/off No
Regulation type modulating Yes
Compatible with Apple HomeKit No
Compatible with Google Assistant No
Compatible with Amazon Alexa No
Max. contact voltage 230 V
With receiver No
Control characteristic Other
Weather-dependent control system No
With tap water circuit No
Number of heater outputs 1
Selector switch for heating and heating with hot water No
Overtime switch No
Temperature readable Yes
Optimisation No
Suitable for heating Yes
Max. contact load 16 A
Differential value 1 K
External sensor Yes
Adjustable differential No
Relative humidity (RH) readable No
Suitable for cooling No